Updating 3D model please wait...
Product Details
| Additional Information |
American Bureau Shipping Certificate No. 00-3K50288-X, Lloyd's Register Certificate No. 01/10075, Germanischer Lloyd Certificate No. 57798-91 HH, DET Norske Veritas Certificate No. P-9100 |
| Tube O.D. (in) |
1/4 |
| Dimension D (mm) |
9.7 |
| Dimension L (mm) |
27.7 |
| Material |
Bodies Glands and Nuts - 316 stainless steel, Automatic Tube Weld Fittings - 316L stainless steel, O - RING - 70 durometer fluorocarbon ( Viton ) is standard on ZCO bodies . 90 durometer fluorocarbon is used with SAE / MS threads. |
| Dimension d (in) |
0.180 |
| Dimension L (in) |
1.090 |
| Dimension L₁ (in) |
0.280 |
| Dimension L₂ (in) |
0.310 |
| Dimension L₁ (mm) |
7.1 |
| Dimension d (mm) |
4.57 |
| Working Pressure (psig) |
6800 |
| Working Pressure (bar) |
460 |
| Dimension D (in) |
0.380 |
| Dimension L₂ (mm) |
7.87 |
| Hex Flat H (in) |
5/8 |
| Size (in) |
1/4 |
| Installation Instructions |
Install ZCO body to existing port, tubing or equipment. Assemble ZCO body with ZCO female nut and gland and tighten nut 1/8 turn with a wrench after finger tight to make sure metal to metal contact. When ZCO body or gland needs soldering, welding or brazing procedures, the O-ring should be removed to prevent possible damage. |